CHLORINE

Service techs can use three methods to measure chlorine residuals in pools:

  • DPD (diethyl-p-phenylene diamine):
  • This is a chemical reagent that reacts with free, or active, chlorine. The sample water is combined with the DPD reagent in a test vial. Between 1 and 3 ppm (industry-recommended chlorine levels), the sample will turn varying shades of red.

    This method also can test for combined chlorine, or chloramines. To get a sense of the combined chlorine, simply perform the initial test for free chlorine and add a second reagent. The resulting color will indicate a total chlorine level. Subtract the previously ascertained free chlorine from the total chlorine level to get the level of combined chlorine.

    One note of caution when doing DPD tests for chlorine: With high chlorine residuals (10 ppm and up), the reagent will bleach out, and the test actually will resemble low chlorine. At this point, a tech is likely to add even more chemicals to the pool, though the levels are too high already.

    If you suspect this phenomenon is at work in the pool you’re testing, simply dilute the test sample by 50 percent with sanitizer-free water and then re-test. Now, a reading of 3 ppm is actually 6 ppm.

  • OTO (ortholtolodine):
  • This reagent has fallen out of favor in recent years due to its inability to distinguish free chlorine from total chlorine, but it still has its advocates.

    To test for total chlorine, add the amount of OTO as specified by the manufacturer to the sample of water in the test cell. Cap the test cell, and invert it to mix (do not use your finger to cover the top of the test cell). A color change (from light yellow to a deep orange) will result. Compare the color of the test sample to the color comparator provided with the kit.

  • FAS-DPD:
  • Another option is the FAS-DPD method. This variation of the traditional DPD method allows users to measure both free and combined chlorine levels as low as 0.2 ppm — the maximum allowable level for combined chlorine, according to most health authorities as well as APSP — and as high as 20 ppm. By contrast, the color comparators used with the standard DPD test generally allow readings at the low end of 0- and 0.5 ppm and at the high end of 5- or maybe 10 ppm.

    In the FAS-DPD titration test, a buffered DPD indicator powder is added to a water sample and reacts with chlorine to produce the pink color characteristic of the standard DPD test. Ferrous ammonium sulfate solution (FAS) then is added drop by drop until the pink color completely and permanently disappears, signaling the endpoint of the reaction.

    To get the reading, the number of drops used to cause this color change is multiplied by the appropriate factor for the size of the water sample (supplied by the manufacturer).

    The distinct change from a vibrant pink to no color at all eliminates the need for color matching. This means when testing samples with a high level of sanitizer, the user does not have to distinguish between relatively close gradations of color or be concerned that any color has been bleached out of the sample. It’s also a boon to the 6- to 8 percent of the population with red-green deficiencies in their color vision.

    The second part of the FAS-DPD test determines the amount of combined chlorine present (that is, mono-, di- or trichloramines) by the number of drops needed to again turn the sample from bright pink to colorless.

    Note: The cost per test is a little higher and the procedure takes a bit longer than other chlorine tests. But many techs keep it on hand for problem pools or to use if they are “color challenged.” Look for FAS-DPD in combination kits and as a stand-alone test.

BROMINE

If the pool or spa you’re testing uses bromine rather than chlorine, you can still test residuals using either OTO or DPD. Follow the same procedures you would when measuring chlorine and multiply the results by a factor of 2.25.

CYANURIC ACID

If you’re measuring for chlorine residuals, you’ll likely be tracking the stabilizer levels as well. Industry-recommended levels are between 30- and 50 ppm for cyanuric acid.

To test CYA levels, a reagent called melamine is used. The melamine will cause the water to become more or less cloudy (the aforementioned turbidity test). Low CYA will produce small particles that give the water a hazy appearance. Higher concentrations produce far more particles and turn the water very cloudy. The turbidity is then measured against a comparator chart depicting the relative visibility of a dot in the test vial, thereby indicating the corresponding CYA reading in parts per million.

pH

Because chlorine only works effectively in certain pH ranges (low 7s to low 8s), it’s just as important to regularly monitor the water’s pH level.

The reagent for testing pH is phenol red — or phenolsulfonephthalein. This is an organic dye that comes in both liquid and tablet form. In a small sample of water, five drops, or one tablet, are added. The resulting colors — yellow (low), red (middle) and purple (high) — will be accurate in a pH range of 6.8 to 8.4.

Two other reagents also are used in pH testing: bromythol blue, with a range of 6.0-7.4, and cresol red, with a range of 7.2-8.8. Phenol red remains the most popular, though, because it closely reflects the pH levels recommended for pools.

Again, be aware that a high sanitizer residual (more than 10 ppm for chlorine, 20 ppm for bromine) can create false pH readings. At these high levels, the sanitizer reacts with the phenol red, which results in false colors. Many test kits include a special neutralizing reagent that, when added prior to testing, ensures accurate results.

If your tests show that the pH needs to be raised or lowered, another test should be done to determine exactly how much adjuster should be added. To lower pH, perform an acid demand test; to raise it, perform a base demand test.

The number of drops required to cause a color change in the water sample correlates to a chart that prescribes the amount of muriatic acid (to lower pH) or soda ash (to raise it) needed to move the pH.

TOTAL ALKALINITY

Total alkalinity (TA) is the water’s ability to neutralize acid, also known as the system’s “pH buffer.”

To test for total alkalinity, two reagents are required for a water sample. First, add the end-point indicator — that is, a chemical that changes colors during the test. The second reagent, titrant, is an acid used to trigger the end-point reaction.

It’s important to perform this test carefully. To properly mix the titrant, the test vial should be gently swirled after each drop is added.

When the titrant is added and just exceeds the water’s ability to neutralize it (it’s an acid, remember), the end-point indicator will suddenly change the water color. This color change happens fast, so pay close attention. Count the number of drops needed to generate this end-point reaction. This determines the concentration of the water’s TA.

According to APSP’s Basic Pool & Spa Technology Manual, Third Edition, the ideal TA level for pool water is between 80- and 120 ppm as calcium carbonate. However, the proper range will vary depending on the type of sanitizer used.

CALCIUM HARDNESS

Testing a pool for calcium hardness is particularly important if you use calcium hypochlorite as the sanitizer, or if the source water is naturally high in calcium. If this is the case, you should initially test both pool and tap water, then test continually for 30 days. After that, remain current on the water’s calcium hardness.

To measure calcium hardness, use a titration method. The first step is to add a special pH buffer to the water sample. This will raise the pH of the sample to approximately 10, the level at which the test is most accurate. Next, an organic dye is added that turns red when it reacts with calcium. Finally, add the titrant: EDTA, also known as ethylenediamine tetraacetic acid.

Add it one drop at a time. When the titrant has combined with all the calcium in the sample, it will turn the water blue. The number of drops required to turn the sample blue correlates to hardness in ppm.

METALS

While regularly testing chlorine and pH makes sense, certain tests, such as the ones for metal, only need to be performed periodically, or if the tech senses trouble and wants to do a little diagnostic investigation.

There is always going to be some sort of metal in pool water, but if you think the levels may be high — if you see staining, for instance — performing a few metal tests would be in order.

Copper and iron are the two most likely culprits. Copper can find its way into pools via copper-based algaecides and the corrosion of copper heat exchangers and heat sinks. Iron is usually introduced from source water — particularly well water.

If you think there’s high metal content (as little as 1 ppm metal can cause staining), it’s best to consider investing in a metal kit.

Typically, kits are colorimetric tests that require two or more reagents. Bicinchoninic acid is popular when testing for copper. It produces shades of purple in the water sample when that metal is present. The common reagent for detecting iron is phenatroline, which produces shades of orange and red.